31
ERROR MESSAGE DEFINITION OF ERROR COMMENTS
056
SHORTED CIRCUIT
RF OUTRIGGER
Excessive load detected in right front outrigger
circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
057
OPEN CIRCUIT
LR OUTRIGGER
A load of less than 70mA detected in left rear
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
058
SHORTED CIRCUIT
LR OUTRIGGER
Excessive load detected in left rear outrigger
circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
059
OPEN CIRCUIT
RR OUTRIGGER
A load of less than 70mA detected in right rear
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
060
SHORTED CIRCUIT
RR OUTRIGGER
Excessive load detected in right rear outrigger
circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
069
OPEN CIRCUIT
PROPORTIONAL
A load of less than 70mA detected in proportional
valve circuit on power-up.
Check for faulty solenoid
coil/wiring at proportional valve.
070
SHORTED CIRCUIT
PROPORTIONAL
Excessive load detected in proportional valve
circuit on power-up.
Check for faulty solenoid
coil/wiring at proportional valve.